ТОВ «ЕМСС»
61016, м Харків,
вул. Андріївська, буд. 41/43
Тел./факс: +38 057 782 19 39
email: info@emcc.pro
www.emcc.pro
QR адреса страницы
equipment materials consulting
0
Товаров в корзине: 0
Наименований: 0
Сумма заказа: 0 грн
Перейти к оформлению

Research Ductility Machine for force ductility test

Choose another model Copy link
Research Ductility Machine for force ductility test
Specifications
Standards ASTM D113, EN 13398, AASHTO T51, ASTM D6084, AASHTO T300

Manufacturer Conrtols

81-PV10C12 - Research Ductility Machine for force ductility test

View full description

The ductility test is performed for determining the ductility of bituminous materials by measuring the elongation before breaking when two ends of briquette specimens are pulled apart at a specified speed and temperature.

Water bath

Insulated stainless steel water bath with a heating system located over the entire base surface and a stainless steel cooling coil (for connection to water mains or chiller) distributed over the three side walls assuring temperature uniformity without water turbulence inside the bath. All parts in contact with water are made of stainless steel.

Carriage displacement

Double-screew rods and mobile carriage enable test speeds from 3 to 200 mm/min. The system also permits the fast return of the carriage at the end of the test (500 mm/min) to reduce dead time and increase productivity. The carriage return is automatic, manual intervention is not required.

Temperature control
  • A closed-loop PID system assures constant temperature from -10 to +60°C, with a water chiller (see accessories).
  • Stainless steel cooling coil.
  • Plate-type base heaters give better temperature uniformity.
  • The thermoregulation system is based on control of the heater (which increases the temperature of the bath) and the control of the flow rate of the cooling coil by an electro-valve. This important feature assures control of the temperature within strict limits and permits the use of suitable standard water chillers.

Load and elongation measurement

Automatic measurement of the elongation by an encoder. Includes a system for measuring forces up to 2000 N (4 x 500 N) with load cells (see accessories).

Testing software
  • Selection of test parameters (speed, temperature etx.) by PC. The test temperature, however, can be set in advance using the control panel of the machine.
  • Specimen failure recognition.
  • Real-time display of load/elongation graph with advanced visualization options (single or multi-graph).
  • Specimen failure recognition.
  • Data acquisition and processing conforming to Standards.
  • Function for multiple test data comparison.
  • Storage of test data.

Machine control

By PC (not included).

Water cooling

This model is proposed without a chiller for use with a suitable cooling system that could be available in the laboratory. It is important, however, that this unit is capable of delivering a flow rate of 6 litres/min, 1 bar, at the minimum temperature of 2°C.

See-through cover

Essential for better temperature control of the bath.

Main features
  • 4 tension line (briquette capacity) x 1500 mm.
  • Easy and free access to the large testing space.
  • Double drive screw rod.
  • Closed-loop PID temperature control system.
  • Stainless steel insulated water bath.
  • Exclusive in-built thermoregulation system compensating the control, optimized by the connection to chiller (optional).
  • High carriage return speed 500 mm/min for greater productivity.
  • Adjustable speed range from 1 to 200 mm.
  • PC-controlled using dedicated software.
  • Includes a system for measuring forces up to 4x500 N with load cells.
  • Temperature range from -10 to 60°C.
  • Elongation measurement by optical system.
  • Real-time load and displacement graphics via PC.
  • Includes a system for measuring forces up to 2000 N (4x500 N).
  • Extensive use of stainless steel for frame, cover and tank.
Manufacturer
Manufacturer Controls
Technical characteristics
Maximum load in tension Max. load and tension load measurement 2000 N to by load cells (4 x 500 N)
Maximum number of simultaneously tested samples 4
Power 1200 W
Type of control Machine control by PC with dicated sofware (PC not included)
Temperature control Thermostatically controlled water bath temperature from 4 to 30°C with water chiller (PID closed-loop control, heater and cooling coil for connection to cold water or water chiller)
Carriage return speed 500 mm/min
Carriage return speed from 1 to 200 mm/min
Max carriage travel 1500 mm
Power supply 230V, 50-60 Hz, 1ph
Dimensions 2434 x 412 x 385 mm
Weight approx. 100 kg

81-B0141 Ductility mould to EN 13398
81-B0141/A Ductility mould conforming to ASTM D6084 and AASHTO T300
81-B0141/B Ductility mould conforming to ASTM D113 and AASHTO T51
81-B0141/EDuctility mould conforming to EN 13589
81-B0142 Ductility mould plate
81-PV10010 Support base for ductility machines
81-PV10020 High precision strain gauge load cell 0-500 N cap
81-PV1012 Water chiller, flow rate 6 l/min at 1 bar, -20°C min. temperature. 3000 W cooling capacity. 230 V, 50-60 Hz, 1 ph